SpO2 & Patient Monitor Accessory Knowledge Center
Six topics that cover the questions buyers actually ask before ordering a compatible sensor, cable or probe: selection, compatibility, materials, cleaning, testing and OEM. Each topic states what we can verify from our own product documentation, links to the pages where that information lives, and flags anything that still needs engineering confirmation instead of filling the gap with a number.
1. Selection — choosing the sensor that fits
Which YKD part matches the monitor on my bench — and what to check before ordering.
Fit is decided by four things, in this order: the connector on the monitor, the OEM’s identification scheme (for example Nellcor OxiMax versus resistor-coded Nellcor), the patient group (adult, paediatric, neonatal, veterinary) and the cable length. Brand names come last, because one brand can carry two or three different sockets across product generations.
Read the socket, not the badge. Every product page in this library states its connector and cable length, and the brand pages put the monitor-to-part mapping on one screen so you do not have to open six pages to compare.
2. Compatibility — cross-reference, coding and trademarks
What “compatible” means here, how to read a cross-referenced part number, and the limit of that claim.
A YKD part number is our number. It is printed next to an OEM model so you can find the part you need, not to imply that the part was made by that OEM. Where an OEM uses a coded identification chip or a resistor coding, the two families are not interchangeable and our tables say so explicitly rather than letting a buyer discover it at the bedside.
Cross-reference is a starting point. The authoritative check is the connector plus the monitor model string, which is why every page ends with an offer to confirm the SKU from a photo of the socket.
3. Materials — jacket, shielding and strain relief
What the cable is made of, and what changes between reusable and single-patient versions.
Reusable sensor and cable jackets are medical-grade TPU: flexible enough for repeated handling, resistant to alcohol wipes, and available with multi-layer shielding on ECG leads where electrosurgery noise is a problem. Single-patient ECG cables use PVC and ABS because they are discarded after one case, and Holter cables are offered in silicone where drape and patient comfort matter more than abrasion resistance.
The question worth asking is not “which material is best” but “what will this cable meet in your department” — repeated disinfection, trolley wheels, MRI-adjacent rooms or veterinary use.
4. Cleaning & reprocessing — what the IFU covers
How reusable parts are cleaned, what single-patient means in practice, and when a part should be retired.
Reusable sensors and cables are wiped with a compatible disinfectant between patients; they are not designed for immersion. Single-patient parts are exactly that — one patient, then disposal — and reusing them is outside both the instructions for use and any warranty discussion.
We do not publish a single universal disinfectant list, because compatibility depends on the part, the agent concentration and your hospital’s protocol. Ask for the IFU of the exact part number and we will send the current revision; for anything beyond that, our after-sales team will confirm with engineering.
5. Testing & documents — what we can actually send
Which reports exist, which are model-specific, and which claims we deliberately do not make on a product page.
The quality system is ISO 13485 and an EU Declaration of Conformity is available on request. Beyond that, documentation is model-specific: an accuracy report, a dimensional drawing or an IFU covers the part it was written for, not the whole catalogue. Where a regulatory listing covers only some models, we state that on the page rather than letting a reader assume the whole range is covered.
If you are preparing a submission, tell us the exact part numbers and the market, and we will send the current document set with its revision dates.
6. OEM / ODM — from requirement to shipment
How a private-label or custom-length programme is actually run, and what we need from you at each step.
The sequence is: requirement (connector, patient group, cable length, labelling) → drawing confirmation → sample → your validation → production → documents with the shipment. Nothing is quoted from a catalogue photo; the drawing is the contract.
Minimum order and lead time are quoted per part and per configuration — a 0.9 m adult clip and a 3 m neonatal soft-tip are not the same production run. Send the part number and the configuration you need and you will get both numbers in writing.
How this library is maintained
Every statement here traces back to one of three sources: the specification table on the individual product page, a document on file (IFU, drawing, test report, certificate), or a written confirmation from engineering. When none of those exist for a field, the field is left as “available on request” and the article says so. That is slower to write and less impressive to read, but it means a buyer can act on what is published.